Reverse Adenoid Curette size 1
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-50123
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-50123AISI 420 Martensitic

1 1/2″ Reverse Adenoid Curette Size 1

4.9 / 5.0•18 Verified OR Evaluations
$163.00$183.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (11% OFF)
  • 1 1/2″ Reverse Adenoid Curette Size 1 designed with a curved configuration for precise adenoid removal.
  • Reversed curved blade design provides a defined cutting profile for ENT procedures.
  • Curved design supports a specialized working orientation within the operative field.
  • Suitable for ENT and pediatric surgery applications requiring a curved curette.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 1 1/2″ Reverse Adenoid Curette Size 1 is a specialized ENT instrument designed for precise adenoid removal in pediatric patients. Its reversed curved blade allows controlled excision in hard-to-access areas, minimizing trauma to surrounding tissue. The ergonomic handle ensures comfort and stability, providing accurate control during delicate procedures.

With an overall length of 1 1/2 inches and a specific blade design, this curette provides a defined cutting profile for ENT applications. The ergonomic design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 1 1/2-inch overall length for controlled manual handling.
  • Reversed curved blade design provides a defined cutting profile.
  • Ergonomic design for specialized working orientation.
  • Designed for precise adenoid removal.
  • Suitable for ENT and pediatric surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Reverse pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeReverse Adenoid Curette
Overall Length1 1/2″
Working End / Blade / JawReversed curved blade design
ConfigurationCurved
Primary FunctionAdenoid Removal
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Pediatric Surgery

The 1 1/2″ Reverse Adenoid Curette Size 1 combines a 1 1/2-inch overall length with a reversed curved blade design.
Its defined working profile is intended for precise adenoid removal in ENT applications.

Design & Function

The Reverse Adenoid Curette features a curved working configuration designed to provide a specialized orientation during adenoid removal. The reversed blade design can assist in positioning the working end according to the requirements of the operative field.

The reversed curved blade provides a defined cutting profile, while the 1 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a curved instrument type.

Surgical Applications

The 1 1/2″ Reverse Adenoid Curette Size 1 may be used for ENT and pediatric surgery applications involving adenoid excision. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Reverse Adenoid Curette before use, paying particular attention to the working end, blade alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Reverse Adenoid Curette appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Reverse Adenoid Curette?
The overall length is 1 1/2 inches.

2. What is the working end / blade or tip design of the instrument?
It features reversed curved blade design.

3. Is this Reverse Adenoid Curette curved or straight?
It features a curved configuration.

4. What is a Reverse Adenoid Curette used for?
It is designed for controlled adenoid removal in ENT applications.

5. What clinical advantage does the reversed blade provide?
The reversed blade provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for pediatric surgery?
It may be used in ENT and pediatric surgery applications where a curved and size 1 curette is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Reverse Adenoid Curette be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.