Rotating Kerrison Rongeur,15mm opening, 90° up, 8″, 1mm -Shaft only – Requires 70-2390 Handle
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-55240
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-55240AISI 420 Martensitic

8″ Kerrison Rongeur Rotating 15mm Opening 90° Up

4.9 / 5.0•18 Verified OR Evaluations
$654.00$854.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $200.00 (23% OFF)
  • 8″ Kerrison Rongeur designed with a 90° up configuration for efficient bone removal.
  • 15 mm jaw opening provides a defined cutting profile for neurosurgical procedures.
  • 90° up design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and spinal surgery applications requiring a Kerrison rongeur.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 8″ Kerrison Rongeur is a specialized neurosurgical instrument designed for efficient bone removal during spinal surgery. Its 15mm jaw opening provides a distinct working orientation that can assist with positioning the working end within the operative field.

With an overall length of 8 inches and a 1mm bite, this rongeur provides a defined cutting profile for neurosurgical applications. The 90° up angle allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 8-inch overall length for controlled manual handling.
  • 15 mm jaw opening provides a defined cutting profile.
  • 90° up configuration for specialized working orientation.
  • Designed for efficient bone removal during spinal surgery.
  • Suitable for neurosurgical applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Kerrison pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeKerrison Rongeur
Overall Length8″
Working End / Blade / Jaw15 mm
Configuration90° Up
Primary FunctionBone Removal
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical

The 8″ Kerrison Rongeur combines an 8-inch overall length with a 15 mm jaw opening and a 90° up configuration.
Its defined working profile is intended for efficient bone removal in neurosurgical applications.

Design & Function

The Kerrison Rongeur features a 90° up working configuration designed to provide a specialized orientation during spinal procedures. The jaw design can assist in positioning the working end according to the requirements of the operative field.

The 15 mm jaw opening provides a defined cutting profile, while the 8-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a Kerrison rongeur.

Surgical Applications

The 8″ Kerrison Rongeur may be used for neurosurgical and spinal surgery applications involving efficient bone removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Kerrison Rongeur before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Kerrison Rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Kerrison Rongeur?
The overall length is 8 inches.

2. What is the working end / blade or tip design of the instrument?
It features 15 mm jaw opening.

3. Is this Kerrison Rongeur curved or straight?
It features a 90° up configuration.

4. What is a Kerrison Rongeur used for?
It is designed for controlled bone removal in neurosurgical applications.

5. What clinical advantage does the 90° up design provide?
The 90° up feature provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and spinal surgery applications where a 90° up Kerrison rongeur is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Kerrison Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.