Russel-Davis Tongue Blade 29x67mm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-51538
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-51538AISI 420 Martensitic

29×67 mm Russel-Davis Tongue Blade

4.9 / 5.0•18 Verified OR Evaluations
$161.00$181.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (11% OFF)
  • 29×67 mm Russel-Davis Tongue Blade designed with a smooth configuration for controlled tongue retraction.
  • 67 mm broad working surface provides a defined retraction profile for ENT procedures.
  • Smooth design supports a specialized working orientation within the operative field.
  • Suitable for ENT and oral surgery applications requiring a smooth tongue blade.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 29×67 mm Russel-Davis Tongue Blade is a specialized ENT instrument designed for controlled retraction of the tongue during oral and ENT procedures. Its broad, smooth surface distributes pressure evenly, minimizing tissue trauma while providing clear access to the oral cavity, pharynx, and larynx.

With an overall length of 29 mm and a width of 67 mm, this tongue blade provides a defined retraction profile for ENT applications. The durable stainless steel construction ensures long-term performance, corrosion resistance, and repeated sterilization capability, supporting controlled manual manipulation during procedures.

Key Features

  • 29 mm x 67 mm overall length for controlled manual handling.
  • Broad working surface provides a defined retraction profile.
  • Smooth configuration for specialized working orientation.
  • Designed for controlled tongue retraction during procedures.
  • Suitable for ENT and oral surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Russel-Davis pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeRussel-Davis Tongue Blade
Overall Length29 mm
Working End / Blade / Jaw67 mm broad working surface
ConfigurationSmooth
Primary FunctionTongue Retraction
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Oral Surgery

The 29×67 mm Russel-Davis Tongue Blade combines a 29 mm overall length with a 67 mm broad working surface and smooth configuration.
Its defined working profile is intended for controlled tongue retraction in ENT applications.

Design & Function

The Russel-Davis Tongue Blade features a smooth working configuration designed to provide a specialized orientation during tongue retraction. The broad working end design can assist in positioning the blade according to the requirements of the operative field.

The 67 mm broad working surface provides a defined retraction profile, while the 29 mm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a smooth tongue blade.

Surgical Applications

The 29×67 mm Russel-Davis Tongue Blade may be used for ENT and oral surgery applications involving tongue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the tongue blade before use, paying particular attention to the working end and surface condition. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Russel-Davis Tongue Blade appropriately to protect its working surface and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Tongue Blade?
The overall length is 29 mm.

2. What is the working end / blade design of the instrument?
It features a 67 mm broad working surface.

3. Is this Tongue Blade smooth or serrated?
It features a smooth configuration.

4. What is a Tongue Blade used for?
It is designed for controlled tongue retraction in ENT applications.

5. What clinical advantage does the smooth design provide?
The smooth design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and oral surgery applications where a smooth tongue blade is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Tongue Blade be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.