5 1/8″ Scheer Crimper Forceps 72mm Shaft
Direct Manufacturer Pricing • Tax Exclusive
- 5 1/8″ Scheer Crimper Forceps designed with a finely contoured configuration for precise crimping of ossicular prosthetics.
- 72 mm shaft provides a defined crimping profile for ENT procedures.
- Finely contoured design supports a specialized working orientation within the operative field.
- Suitable for ENT and otologic surgery applications requiring a finely contoured crimper forceps.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 5 1/8″ Scheer Crimper Forceps is a specialized ENT instrument designed for precise crimping of ossicular prosthetics, fine wires, and small implants during otologic procedures. Its finely contoured jaws provide a distinct working orientation that can assist with positioning the working end within the operative field.
With an overall length of 5 1/8 inches and a 72 mm shaft, this crimper forceps provides a defined crimping profile for ENT applications. The ergonomic design allows the working end to approach delicate anatomical structures from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 5 1/8-inch overall length for controlled manual handling.
- 72 mm shaft provides a defined crimping profile.
- Finely contoured jaw configuration for specialized working orientation.
- Designed for precise crimping of ossicular prosthetics and small implants.
- Suitable for ENT and otologic surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Scheer pattern for professional ENT instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Scheer Crimper Forceps |
| Overall Length | 5 1/8″ |
| Working End / Blade / Jaw | 72 mm shaft |
| Configuration | Finely Contoured |
| Primary Function | Crimping of Ossicular Prosthetics |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | ENT / Otologic Surgery |
The 5 1/8″ Scheer Crimper Forceps combines a 5 1/8-inch overall length with a 72 mm shaft and finely contoured configuration.
Its defined working profile is intended for precise crimping of ossicular prosthetics in ENT applications.
Design & Function
The Scheer Crimper Forceps features a finely contoured working configuration designed to provide a specialized orientation during otologic procedures. The jaw design can assist in positioning the working end according to the requirements of the operative field.
The 72 mm shaft provides a defined crimping profile, while the 5 1/8-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a finely contoured crimper forceps.
Surgical Applications
The 5 1/8″ Scheer Crimper Forceps may be used for ENT and otologic surgery applications involving precise crimping of delicate structures. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the crimper forceps before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the crimper forceps appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Crimper Forceps?
The overall length is 5 1/8 inches.
2. What is the working end / blade or tip design of the instrument?
It features 72 mm shaft.
3. Is this Crimper Forceps curved or straight?
It features a finely contoured configuration.
4. What is a Crimper Forceps used for?
It is designed for controlled crimping of ossicular prosthetics in ENT applications.
5. What clinical advantage does the finely contoured design provide?
The design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for ENT surgery?
It may be used in ENT and otologic surgery applications where a finely contoured crimper forceps is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Crimper Forceps be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.