Simcoe DB I-A Unit – 23g
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-65981
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
OtherSKU: SP-65981AISI 420 Martensitic

23G Simcoe Double-Barrel Irrigation/Aspiration Unit

4.9 / 5.0•18 Verified OR Evaluations
$160.00$184.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $24.00 (13% OFF)
  • 23G Simcoe Double-Barrel Irrigation/Aspiration Unit designed with a dual-lumen configuration for simultaneous irrigation and aspiration.
  • 23G tip size provides a defined aspiration profile for ophthalmic procedures.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Suitable for ophthalmic and cataract surgery applications requiring a dual-lumen irrigation/aspiration unit.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 23G Simcoe Double-Barrel Irrigation/Aspiration Unit is a specialized ophthalmic instrument designed for simultaneous irrigation and aspiration during cataract surgery. Its dual-lumen design allows balanced fluid inflow and controlled aspiration, helping maintain a stable anterior chamber while effectively removing cortical remnants.

With an overall length of and a fine 23-gauge tip, this irrigation/aspiration unit provides precise fluid control and reduces trauma to intraocular tissues. The ergonomic design allows the working end to approach the anterior chamber from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for controlled manual handling.
  • 23G tip size provides a defined aspiration profile.
  • Dual-lumen configuration for specialized fluid management.
  • Designed for simultaneous irrigation and aspiration.
  • Suitable for ophthalmic and cataract surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Simcoe pattern for professional ophthalmic instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeSimcoe Double-Barrel Irrigation/Aspiration Unit
Overall Length
Working End / Tip23G tip
ConfigurationDual-lumen
Primary FunctionIrrigation and Aspiration
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeOphthalmic / Cataract Surgery

The 23G Simcoe Double-Barrel Irrigation/Aspiration Unit combines a overall length with a 23G tip and dual-lumen configuration.
Its defined working profile is intended for simultaneous irrigation and aspiration in ophthalmic applications.

Design & Function

The Simcoe Double-Barrel Irrigation/Aspiration Unit features a dual-lumen configuration designed to provide specialized fluid management during cataract surgery. The fine 23-gauge tip can assist in positioning the working end according to the requirements of the operative field.

The 23G tip provides a defined aspiration profile, while the overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ophthalmic procedures requiring a dual-lumen irrigation/aspiration unit.

Surgical Applications

The 23G Simcoe Double-Barrel Irrigation/Aspiration Unit may be used for ophthalmic and cataract surgery applications involving simultaneous irrigation and aspiration of lens material. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the irrigation/aspiration unit before use, paying particular attention to the working end and tip alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the irrigation/aspiration unit appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this irrigation/aspiration unit?
The overall length is .

2. What is the working end / tip design of the instrument?
It features 23G tip.

3. Is this irrigation/aspiration unit dual-lumen?
It features a dual-lumen configuration.

4. What is a Simcoe irrigation/aspiration unit used for?
It is designed for controlled irrigation and aspiration in ophthalmic applications.

5. What clinical advantage does the dual-lumen design provide?
The dual-lumen design provides balanced fluid inflow and controlled aspiration for maintaining a stable anterior chamber.

6. Is this instrument suitable for cataract surgery?
It may be used in ophthalmic and cataract surgery applications where a dual-lumen irrigation/aspiration unit is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the irrigation/aspiration unit be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.