Slaphammer for 79 0176 Surgical Instrument
Direct Manufacturer Pricing • Tax Exclusive
The Slaphammer for 79 0176 is a specialized surgical instrument designed to support controlled extraction and removal procedures when used with compatible surgical systems. Its impact-based mechanism helps provide a practical solution for instrument removal tasks in orthopedic and related surgical applications.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Slaphammer for 79 0176 is a specialized surgical instrument intended to assist with controlled extraction procedures using a compatible instrument assembly. Slaphammers are commonly designed to generate a pulling force through a sliding weight mechanism, allowing the operator to apply a series of controlled impacts when removing a compatible component. The exact function and compatibility of this model should be confirmed against the manufacturer's specifications before clinical use.
In orthopedic surgery, extraction instruments may be required during revision procedures, implant removal, and the disassembly of compatible surgical components. A slaphammer can help transfer force along the instrument's axis, supporting controlled removal when a component cannot be withdrawn using a conventional pulling technique. The Slaphammer for 79 0176 should only be used for applications approved for its specific design and compatible attachments.
Design and Functional Features
A typical slaphammer incorporates a sliding weight mounted on a shaft with a striking stop. Moving the weight along the shaft creates an impact that transfers force to a connected extraction attachment. This mechanism can help the operator apply a directed pulling action without relying exclusively on continuous manual traction.
The effectiveness of a slaphammer depends on its construction, attachment interface, weight, and compatibility with the instrument assembly. Before using the Slaphammer for 79 0176, healthcare professionals should verify the connection type, intended application, and operating instructions. The product title alone does not establish its dimensions, weight, material grade, or compatibility with a particular implant system.
Surgical Applications
Slaphammers may be used in selected orthopedic and surgical procedures that require the extraction of compatible instruments or components. Depending on the specific model and approved attachments, potential applications can include implant extraction, removal of instrument components, and revision surgery. Not every slaphammer is suitable for every extraction procedure, so the intended use must be established from the manufacturer's documentation.
When appropriately matched to the surgical system, a slaphammer can provide a more directed extraction force and help reduce the need for improvised removal techniques. Correct attachment, stable instrument alignment, and controlled operation are essential to support safe handling and reduce the risk of damage to the instrument, implant, or surrounding structures.
Material, Durability, and Handling
The material specification for the Slaphammer for 79 0176 has not been provided. Surgical extraction instruments are often manufactured from durable medical-grade metals selected to withstand repeated mechanical loading and appropriate reprocessing. However, stainless steel grade, surface finish, corrosion resistance, and other material characteristics should be verified using the manufacturer's product information rather than assumed.
Proper handling helps maintain the instrument's mechanical performance. Before each use, inspect the shaft, sliding weight, stops, connection points, and any compatible attachments for wear, deformation, cracks, or other visible damage. Any instrument showing signs of damage or unreliable movement should be removed from service and evaluated according to institutional procedures.
Cleaning, Sterilization, and Maintenance
Reusable surgical instruments must be cleaned and reprocessed according to the manufacturer's validated instructions. Remove visible soil promptly after use, disassemble removable components when instructed, and clean all accessible surfaces and connection areas using approved methods. The sliding mechanism and attachment interface require particular attention because retained debris can interfere with movement and assembly.
Sterilization parameters depend on the instrument's materials, construction, and manufacturer validation. Do not assume that a particular steam sterilization cycle or other method is appropriate without confirming the instructions for use. After cleaning and sterilization, inspect the instrument for cleanliness, corrosion, mechanical wear, and proper function before returning it to service.
The Slaphammer for 79 0176 can be considered for professional surgical instrument inventories where its specific design and intended application meet procedural requirements. Confirming the exact model, compatible attachments, material specifications, and reprocessing instructions helps support appropriate instrument selection, maintenance, and reliable use in clinical environments.
Key Features
Product identification: Slaphammer for 79 0176.
Extraction function: Intended to support controlled removal procedures with compatible components.
Impact-based mechanism: Slaphammer designs use a sliding weight to generate a directed extraction force.
Orthopedic applications: May support selected implant or instrument extraction procedures when approved for the specific model.
Compatible attachments: Requires verification of the connection interface and approved accessories.
Controlled operation: Supports an axial pulling action when correctly assembled and used.
Professional instrument use: Intended for applications determined by the manufacturer's instructions.
Inspection requirements: Shaft, sliding weight, stops, and connections should be checked before use.
Reprocessing: Cleaning and sterilization must follow validated manufacturer instructions.
Durability considerations: Material grade and service life should be confirmed from product documentation.
Product Specifications
Specification | Details |
|---|---|
Product Name | Slaphammer for 79 0176 |
Instrument Type | Slaphammer / extraction instrument |
Model or Reference | 79 0176 |
Primary Function | Controlled extraction with compatible components |
Specialty | Potential orthopedic and surgical applications |
Operating Mechanism | Sliding-weight impact mechanism typical of slaphammers; confirm model design |
Material | Not specified |
Overall Length | Not specified |
Weight | Not specified |
Attachment Compatibility | Requires manufacturer verification |
Reusable Status | Confirm manufacturer instructions |
Cleaning Method | According to validated manufacturer instructions |
Sterilization Method | According to validated manufacturer instructions |
Frequently Asked Questions
1. What is a Slaphammer for 79 0176 used for?
The Slaphammer for 79 0176 is identified as a specialized extraction instrument. Its exact intended application should be confirmed with the manufacturer to establish which components or assemblies it is designed to remove.
2. How does a surgical slaphammer work?
A typical surgical slaphammer uses a sliding weight that moves along a shaft and strikes a stop, transferring an impact force to a connected attachment. This action produces a pulling force that assists with extraction.
3. Can the Slaphammer for 79 0176 be used for orthopedic implant removal?
Slaphammers are used in certain orthopedic extraction procedures, including selected implant removal applications. Whether this particular model is suitable depends on its design, compatible attachments, and the manufacturer's approved indications.
4. What material is the Slaphammer for 79 0176 made from?
The material has not been confirmed from the supplied product title. Consult the manufacturer's specifications to verify whether the instrument is made from stainless steel or another material.
5. Is the Slaphammer for 79 0176 reusable?
Its reusable status must be confirmed using the manufacturer's instructions. If designated for reuse, the instrument must be inspected, cleaned, and reprocessed according to validated procedures.
6. How should a surgical slaphammer be cleaned and sterilized?
Follow the manufacturer's validated cleaning and sterilization instructions. Pay particular attention to moving parts and attachment interfaces, and inspect the instrument after reprocessing to ensure that it remains clean and functional.
7. How can I confirm compatibility with an existing surgical instrument set?
Verify the reference number 79 0176, attachment interface, intended application, and approved accessories with the manufacturer or supplier before connecting the slaphammer to another instrument syste