Standard Anastomosis Clamp 6 1 2″ (DeBakey Jaw)
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-83791
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-83791AISI 420 Martensitic

Standard Anastomosis Clamp 6.5 Inch DeBakey Jaw

4.9 / 5.0•18 Verified OR Evaluations
$80.00$100.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (20% OFF)

The Standard Anastomosis Clamp 6 1/2″ with DeBakey Jaw is a specialized surgical instrument designed for controlled clamping in vascular and anastomotic procedures. Its DeBakey-style jaw configuration is intended to provide a suitable grip when handling delicate vascular structures, subject to the instrument's specific design and manufacturer instructions.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Standard Anastomosis Clamp 6 1/2″ (DeBakey Jaw) is a specialized surgical instrument intended for vascular procedures requiring controlled clamping. Anastomosis refers to the joining of structures such as blood vessels, and appropriate clamping instruments can help qualified surgeons manage blood flow and maintain control of the operative field during selected stages of a procedure.

The instrument's stated length of 6 1/2 inches provides an important reference for surgical instrument selection. Overall length can influence handling, reach, and access within the operative field. However, the most appropriate instrument depends on the surgical approach, the anatomy involved, and the surgeon's requirements. Buyers should confirm whether the listed measurement represents the complete instrument length and review the manufacturer's specifications before purchase.

The DeBakey jaw designation identifies the gripping pattern associated with the instrument. DeBakey-style jaws are commonly associated with atraumatic vascular instrument designs intended to provide controlled engagement with delicate tissue. The exact jaw profile, serration pattern, clamping pressure, and intended vessel size for this particular clamp are not specified by the product title. These characteristics should be confirmed with the manufacturer to ensure suitability for the intended procedure.

Anastomosis clamps are selected according to the specific requirements of vascular surgery and other procedures involving vessel control. Their design must match the intended tissue, surgical technique, and required level of occlusion. The Standard Anastomosis Clamp should only be used by appropriately trained surgical professionals who understand its operating mechanism and limitations. Its suitability for a specific procedure cannot be established by the product name alone.

The construction material is not stated in the product title. Surgical clamps are available in different materials and configurations, and the material affects durability, maintenance, and reprocessing requirements. Buyers should verify the exact material grade, surface finish, locking mechanism, and whether the clamp is designed for repeated use. These details should not be assumed without manufacturer documentation.

Before use, inspect the clamp's jaws for alignment, damage, wear, or irregularities. Check that the handles and any locking mechanism operate as intended. The instrument should close smoothly and consistently according to its design. Any clamp showing visible damage or unreliable function should be removed from service and assessed by qualified personnel.

Cleaning, disinfection, and sterilization must follow the manufacturer's validated instructions and the healthcare facility's infection-prevention protocols. Pay particular attention to the jaw surfaces and any hinged or locking components where residue may accumulate. The instrument's actual material and design determine which cleaning agents and sterilization methods are appropriate.

For hospitals, vascular surgery departments, operating rooms, and surgical instrument suppliers, the Standard Anastomosis Clamp 6 1/2″ (DeBakey Jaw) may be considered when its verified specifications match the intended clinical application. Confirming the dimensions, jaw design, material, locking mechanism, and reprocessing requirements supports informed purchasing and responsible instrument management.

Key Features

  • Standard anastomosis surgical clamp

  • DeBakey-style jaw configuration

  • Overall length stated as 6 1/2 inches

  • Intended for controlled clamping in appropriate vascular procedures

  • Designed for professional surgical environments

  • Jaw profile and gripping characteristics require confirmation

  • Material and grade not specified

  • Locking mechanism details not provided

  • Intended vessel size and clamping range require manufacturer confirmation

  • Requires inspection before each use

  • Cleaning and sterilization must follow manufacturer instructions

Product Specifications

Specification

Details

Product Name

Standard Anastomosis Clamp

Instrument Type

Anastomosis clamp

Jaw Design

DeBakey jaw

Overall Length

6 1/2 inches

Approximate Metric Length

16.5 cm

Surgical Category

Vascular surgery instrumentation

Primary Function

Controlled clamping for appropriate surgical applications

Material

Not specified

Jaw Profile

DeBakey style; exact configuration to be confirmed

Locking Mechanism

Confirm with manufacturer

Reusability

Confirm with manufacturer

Sterilization Compatibility

Follow manufacturer instructions

Intended Users

Qualified surgical professionals

Frequently Asked Questions

1. What is a Standard Anastomosis Clamp used for?

An anastomosis clamp is intended to support controlled clamping during appropriate surgical procedures, including selected procedures involving blood vessels. The exact application depends on the clamp's design and manufacturer instructions.

2. What is the benefit of a DeBakey jaw?

DeBakey-style jaws are associated with vascular instrument designs intended to provide controlled engagement with delicate tissue. The actual gripping characteristics of this model should be verified with the manufacturer.

3. How long is this Standard Anastomosis Clamp?

The product title specifies a length of 6 1/2 inches, approximately 16.5 cm.

4. What material is this anastomosis clamp made from?

The material is not specified in the supplied product title. Confirm the material and grade with the manufacturer or supplier.

5. Is this clamp suitable for vascular surgery?

It is identified as an anastomosis clamp with DeBakey jaws. Suitability for a particular vascular procedure depends on the jaw configuration, clamping characteristics, and manufacturer's intended use.

6. Is the Standard Anastomosis Clamp reusable?

Reusability depends on the manufacturer's labeling and instructions. Confirm whether the instrument is designed for reuse and follow the specified reprocessing procedures.

7. How should the clamp be cleaned and sterilized?

Follow the manufacturer's validated cleaning, inspection, packaging, and sterilization instructions. Do not assume a specific reprocessing method is suitable without confirming compatibility.