T-Line Blunt Retractor Blade 20 x 60mm Gold with Conical Hub
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-54748
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-54748AISI 420 Martensitic

20 x 60mm T-Line Blunt Retractor Blade Gold with Conical Hub

4.9 / 5.0•18 Verified OR Evaluations
$285.00$316.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $31.00 (10% OFF)
  • 20 x 60mm T-Line Blunt Retractor Blade Gold with Conical Hub designed with a blunt configuration for atraumatic tissue retraction.
  • 20 mm working width provides a defined retraction profile for spinal procedures.
  • Blunt design supports a specialized working orientation within the operative field.
  • Suitable for spinal and mid-depth surgery applications requiring a blunt retractor blade.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 20 x 60mm T-Line Blunt Retractor Blade Gold with Conical Hub is a specialized surgical instrument designed for precise and atraumatic tissue retraction in mid-depth spinal procedures. Its blunt working edge reduces tissue trauma while maintaining effective retraction, ensuring optimal engagement during surgical interventions.

With an overall length of 60 mm and a width of 20 mm, this retractor blade provides a defined retraction profile for spinal applications. The gold coating enhances durability, corrosion resistance, and visibility during surgery, allowing for controlled reach in confined operative fields.

Key Features

  • 60 mm overall length for controlled reach in confined spaces.
  • 20 mm working width provides broad, stable tissue engagement.
  • Blunt configuration minimizes tissue trauma during retraction.
  • Designed for precise tissue retraction in spinal procedures.
  • Suitable for mid-depth spinal surgery applications.
  • Supports effective positioning of tissue within the operative field.
  • Specialized T-Line pattern for professional surgical instrument sets.
  • Corrosion-resistant surgical-grade gold coating.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeT-Line Blunt Retractor Blade
Overall Length60 mm
Working End / Blade / Jaw20 mm
ConfigurationBlunt
Primary FunctionTissue Retraction
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeSpinal Surgery

The 20 x 60mm T-Line Blunt Retractor Blade Gold with Conical Hub combines a 60 mm overall length with a 20 mm working width and blunt configuration.
Its defined working profile is intended for precise tissue retraction in spinal applications.

Design & Function

The T-Line Blunt Retractor Blade features a blunt working configuration designed to provide a specialized orientation during spinal procedures. The blunt edge design can assist in positioning the working end according to the requirements of the operative field.

The 20 mm working width provides a defined retraction profile, while the 60 mm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring a blunt retractor blade.

Surgical Applications

The 20 x 60mm T-Line Blunt Retractor Blade Gold with Conical Hub may be used for spinal and mid-depth surgical applications involving atraumatic tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the T-Line Blunt Retractor Blade before use, paying particular attention to the working end and blunt edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the T-Line Blunt Retractor Blade appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this T-Line Blunt Retractor Blade?
The overall length is 60 mm.

2. What is the working end / blade design of the instrument?
It features 20 mm working width.

3. Is this T-Line Blunt Retractor Blade curved or straight?
It features a blunt configuration.

4. What is a T-Line Blunt Retractor Blade used for?
It is designed for controlled tissue retraction in spinal applications.

5. What clinical advantage does the blunt design provide?
The blunt design provides a specialized working orientation for minimizing tissue trauma during retraction.

6. Is this instrument suitable for spinal surgery?
It may be used in spinal and mid-depth surgical applications where a blunt retractor blade is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the T-Line Blunt Retractor Blade be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.