T-Line Step-down Frame for Conical Hub blades only
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-54745
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-54745AISI 420 Martensitic

T-LINE Step-Down Frame for Conical Hub Blades

4.9 / 5.0•18 Verified OR Evaluations
$2300.00$2375.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $75.00 (3% OFF)
  • T-LINE Step-Down Frame for Conical Hub Blades designed with a step-down configuration for controlled tissue retraction.
  • Compatible with conical hub blades provides a defined retraction profile for spinal procedures.
  • Step-down design supports a specialized working orientation within the operative field.
  • Suitable for spinal surgery applications requiring a reliable retraction frame.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The T-LINE Step-Down Frame for Conical Hub Blades is a specialized retractor designed for controlled, multi-level tissue retraction during spinal procedures. Its step-down profile allows staged retraction, enabling gradual tissue displacement and improved exposure while minimizing tissue stress. The frame supports precise blade positioning and stability within confined or multi-depth operative fields.

With a robust construction from durable, sterilization-compatible materials, this retractor provides a reliable solution for enhancing visibility and access during surgical interventions. The design ensures that the T-LINE blades can be effectively utilized to achieve optimal retraction and exposure of the surgical site.

Key Features

  • Designed for controlled multi-level tissue retraction to enhance surgical visibility.
  • Step-down profile allows for gradual tissue displacement.
  • Supports precise blade positioning for improved stability during procedures.
  • Constructed from durable, sterilization-compatible materials.
  • Minimizes tissue stress during retraction.
  • Suitable for spinal and multi-depth operative field applications.
  • Enhances exposure while maintaining tissue integrity.
  • Corrosion-resistant and reusable surgical-grade materials.

Technical Specifications

SpecificationDetails
Instrument TypeT-LINE Step-Down Frame
Overall LengthStandardized dimensions apply
Working End / Blade / JawCompatible with conical hub blades
ConfigurationStep-down
Primary FunctionTissue retraction
MaterialDurable sterilization-compatible materials
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeSpinal Surgery

The T-LINE Step-Down Frame for Conical Hub Blades combines a robust design with a step-down configuration for effective tissue retraction.
Its defined profile is intended for enhancing visibility and access in spinal surgery applications.

Design & Function

The T-LINE Step-Down Frame features a step-down configuration designed to provide a specialized orientation during spinal procedures. The frame's design assists in positioning the blades according to the requirements of the operative field.

The compatibility with conical hub blades provides a defined retraction profile, while the durable construction allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring effective tissue retraction.

Surgical Applications

The T-LINE Step-Down Frame for Conical Hub Blades may be used for spinal surgery applications involving multi-level tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the T-LINE Step-Down Frame before use, paying particular attention to the stability and compatibility with the blades. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the T-LINE Step-Down Frame appropriately to protect its structure and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this T-LINE Step-Down Frame?
The overall length is standardized dimensions apply.

2. What is the working end / blade or tip design of the instrument?
It features compatibility with conical hub blades.

3. Is this T-LINE Step-Down Frame curved or straight?
It features a step-down configuration.

4. What is a T-LINE Step-Down Frame used for?
It is designed for controlled tissue retraction in spinal surgery applications.

5. What clinical advantage does the step-down design provide?
The step-down design provides a specialized working orientation for positioning the blades within the operative field.

6. Is this instrument suitable for spinal surgery?
It may be used in spinal surgery applications where a step-down retraction frame is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the T-LINE Step-Down Frame be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.