8 3/4″ Teardrop Dissector Straight Shaft 90° Angled
Direct Manufacturer Pricing • Tax Exclusive
- 8 3/4″ Teardrop Dissector designed with a straight shaft configuration for precise tissue dissection and manipulation.
- Teardrop-shaped tip provides a defined dissection profile for neurosurgical procedures.
- Straight shaft design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and spinal surgery applications requiring a straight shaft dissector.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8 3/4″ Teardrop Dissector is a specialized neurosurgical instrument designed for precise tissue dissection and manipulation in neurosurgical, spinal, and cranial procedures. Its teardrop-shaped tip allows controlled separation of delicate tissues, while the 90° angled design provides optimal access to confined or angled anatomical spaces.
With an overall length of 8 3/4 inches and a straight shaft configuration, this dissector provides a defined dissection profile for neurosurgical applications. The angled design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 8 3/4-inch overall length for controlled manual handling.
- Straight shaft configuration provides a defined dissection profile.
- 90° angled design for specialized working orientation.
- Designed for precise tissue dissection and manipulation.
- Suitable for neurosurgical, spinal, and cranial applications.
- Supports positioning of the working end within the operative field.
- Specialized Teardrop pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Teardrop Dissector |
| Overall Length | 8 3/4″ |
| Working End / Blade / Jaw | Teardrop-shaped tip |
| Configuration | Straight Shaft |
| Primary Function | Tissue Dissection and Manipulation |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical / Spinal Surgery |
The 8 3/4″ Teardrop Dissector combines an 8 3/4-inch overall length with a teardrop-shaped tip and straight shaft configuration.
Its defined working profile is intended for precise tissue dissection and manipulation in neurosurgical applications.
Design & Function
The Teardrop Dissector features a straight shaft configuration designed to provide a specialized orientation during tissue dissection. The 90° angled design can assist in positioning the working end according to the requirements of the operative field.
The teardrop-shaped tip provides a defined dissection profile, while the 8 3/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a straight shaft instrument.
Surgical Applications
The 8 3/4″ Teardrop Dissector may be used for neurosurgical and spinal surgery applications involving precise tissue dissection and manipulation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Teardrop Dissector before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Teardrop Dissector appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Teardrop Dissector?
The overall length is 8 3/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features a teardrop-shaped tip.
3. Is this Teardrop Dissector curved or straight?
It features a straight shaft configuration.
4. What is a Teardrop Dissector used for?
It is designed for controlled tissue dissection and manipulation in neurosurgical applications.
5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and spinal surgery applications where a straight shaft Teardrop Dissector is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Teardrop Dissector be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.