Trocar Incision Closure Device shaft 3mm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-62710
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
OtherSKU: SP-62710AISI 420 Martensitic

3mm Trocar Incision Closure Device Shaft

4.9 / 5.0•18 Verified OR Evaluations
$1585.00$1785.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $200.00 (11% OFF)
  • 3mm Trocar Incision Closure Device Shaft designed with a slim configuration for safe closure of trocar and port site incisions.
  • 3mm shaft diameter provides a defined closure profile for laparoscopic procedures.
  • Slim design supports a specialized working orientation within the operative field.
  • Suitable for laparoscopic and minimally invasive surgery applications requiring a slim closure device.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 3mm Trocar Incision Closure Device Shaft is a specialized laparoscopic instrument designed for safe and efficient closure of trocar or port site incisions during minimally invasive procedures. Its slim 3mm shaft diameter allows for easy insertion through small incisions, facilitating accurate passage of sutures through fascial and tissue layers to securely close the incision after removal of laparoscopic trocars, thereby reducing the risk of postoperative hernia and wound complications.

With an overall length of and a 3mm shaft diameter, this closure device provides a defined suturing profile for laparoscopic applications. The ergonomic design allows the working end to approach the incision site from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for precise suturing.
  • 3mm shaft diameter provides a defined closure profile.
  • [Configuration, e.g. Slim design] for specialized working orientation.
  • Designed for safe closure of trocar and port site incisions.
  • Suitable for laparoscopic surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Trocar pattern for professional laparoscopic instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeTrocar Incision Closure Device
Overall Length
Working End / Blade / Jaw3mm shaft diameter
ConfigurationSlim
Primary FunctionClosure of Trocar and Port Site Incisions
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeLaparoscopic Surgery

The 3mm Trocar Incision Closure Device Shaft combines a overall length with a 3mm shaft diameter and slim configuration.
Its defined working profile is intended for safe closure of trocar and port site incisions in laparoscopic applications.

Design & Function

The Trocar Incision Closure Device features a slim working configuration designed to provide a specialized orientation during laparoscopic procedures. The 3mm shaft diameter can assist in positioning the working end according to the requirements of the operative field.

The 3mm shaft diameter provides a defined closure profile, while the overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for laparoscopic procedures requiring a slim closure device.

Surgical Applications

The 3mm Trocar Incision Closure Device Shaft may be used for laparoscopic and minimally invasive surgery applications involving the closure of trocar and port site incisions. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Trocar Incision Closure Device before use, paying particular attention to the working end and shaft alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Trocar Incision Closure Device appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Trocar Incision Closure Device?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features 3mm shaft diameter.

3. Is this Trocar Incision Closure Device curved or straight?
It features a Slim configuration.

4. What is a Trocar Incision Closure Device used for?
It is designed for controlled closure of trocar and port site incisions in laparoscopic applications.

5. What clinical advantage does the slim design provide?
The slim design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for laparoscopic surgery?
It may be used in laparoscopic and minimally invasive surgery applications where a slim closure device is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Trocar Incision Closure Device be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.