
45cm Wave-Jaw Grasper Non-Rotating Single Action
Direct Manufacturer Pricing • Tax Exclusive
- 45cm Wave-Jaw Grasper Non-Rotating Single Action designed with a non-rotating configuration for secure tissue manipulation.
- Wave-patterned jaws provide a defined grasping profile for laparoscopic procedures.
- Non-rotating design supports a specialized working orientation within the operative field.
- Suitable for laparoscopic and minimally invasive surgical applications requiring a non-rotating grasper.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 45cm Wave-Jaw Grasper Non-Rotating Single Action is a specialized laparoscopic instrument designed for secure and controlled tissue manipulation during surgical procedures requiring extended reach. Its wave-patterned jaws provide a reliable grip without crushing tissue, while the non-rotating shaft offers stability during precise surgical maneuvers.
With an overall length of 45 cm and a single-action mechanism, this grasper provides a defined grasping profile for laparoscopic applications. The ergonomic design allows the working end to approach tissue from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 45 cm overall length for extended reach and controlled handling.
- Wave-patterned jaws provide a defined grasping profile.
- Non-rotating configuration for enhanced stability during use.
- Designed for secure tissue manipulation in laparoscopic procedures.
- Suitable for minimally invasive surgical applications.
- Supports positioning of the working end within the operative field.
- Specialized Wave-Jaw pattern for professional laparoscopic instrument sets.
- Corrosion-resistant surgical-grade stainless steel and polymer construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Wave-Jaw Grasper |
| Overall Length | 45 cm |
| Working End / Blade / Jaw | Wave-patterned jaws |
| Configuration | Non-Rotating |
| Primary Function | Tissue Manipulation |
| Material | AISI 420 German Stainless Steel |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Laparoscopic Surgery |
The 45cm Wave-Jaw Grasper Non-Rotating Single Action combines a 45 cm overall length with wave-patterned jaws and a non-rotating configuration.
Its defined working profile is intended for secure tissue manipulation in laparoscopic applications.
Design & Function
The Wave-Jaw Grasper features a non-rotating working configuration designed to provide a specialized orientation during laparoscopic procedures. The wave-patterned jaw design can assist in positioning the working end according to the requirements of the operative field.
The wave-patterned jaws provide a defined grasping profile, while the 45 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for laparoscopic procedures requiring a non-rotating instrument type.
Surgical Applications
The 45cm Wave-Jaw Grasper Non-Rotating Single Action may be used for laparoscopic and minimally invasive surgical applications involving secure tissue manipulation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Wave-Jaw Grasper before use, paying particular attention to the working end, jaw alignment, and gripping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Wave-Jaw Grasper appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Wave-Jaw Grasper?
The overall length is 45 cm.
2. What is the working end / blade or tip design of the instrument?
It features wave-patterned jaws.
3. Is this Wave-Jaw Grasper curved or straight?
It features a non-rotating configuration.
4. What is a Wave-Jaw Grasper used for?
It is designed for controlled tissue manipulation in laparoscopic applications.
5. What clinical advantage does the non-rotating design provide?
The non-rotating feature provides enhanced stability for positioning the working end within the operative field.
6. Is this instrument suitable for laparoscopic surgery?
It may be used in laparoscopic and minimally invasive applications where a non-rotating grasper is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Wave-Jaw Grasper be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
