Weitlaner Retractor Sharp Prongs 16 cm (3×4)
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-63496
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-63496AISI 420 Martensitic

Weitlaner Retractor Sharp Prongs 16cm 3x4

4.9 / 5.0•18 Verified OR Evaluations
$100.00$120.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (17% OFF)

The Weitlaner Retractor with sharp prongs is a self-retaining surgical instrument designed to maintain tissue separation and improve operative exposure. Measuring 16 cm and featuring a 3x4 prong configuration, it provides a practical option for surgical procedures requiring secure tissue engagement.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Weitlaner Retractor with Sharp Prongs is a self-retaining surgical instrument designed to hold tissues apart and maintain access to the operative field. With an overall length of 16 cm (160 mm) and a 3x4 prong configuration, this retractor is intended for surgical settings where controlled tissue retraction is required. Its sharp prongs are designed to engage tissue securely when this tip style is appropriate for the procedure.

Self-Retaining Retractor Design

Weitlaner retractors feature an opening mechanism and retaining system that help maintain tissue separation without requiring continuous manual traction. Once positioned correctly, the retractor can hold the operative area open, allowing the surgical team to work with improved visibility and access.

The exact locking mechanism and adjustment design of this model are not specified in the product title. These details should be confirmed with the manufacturer before purchase. Correct adjustment is essential because excessive retraction pressure may cause tissue trauma.

Sharp 3x4 Prong Configuration

This model features sharp prongs in a 3x4 configuration. The designation describes the stated arrangement of prongs on the opposing working ends. Sharp tips are intended to provide more secure engagement with suitable tissue than blunt tips in applications where controlled anchoring is required.

The choice between sharp and blunt prongs depends on the procedure, tissue characteristics, and clinician preference. Sharp prongs require particular care during placement and removal because they can penetrate or damage tissue if used incorrectly. The exact prong dimensions and arrangement should be verified against the manufacturer's specifications.

16 cm Overall Length

The instrument measures 16 cm (160 mm) in overall length. This size may be suitable for surgical applications requiring a compact retractor with additional reach compared with shorter models. However, overall length alone does not determine the maximum opening, retraction depth, or suitability for a particular anatomical site.

The blade dimensions, prong length, opening range, and working profile are not provided in the product title. Confirm these measurements before ordering if the retractor must fit a specific surgical instrument set or procedural requirement.

Surgical Applications and Handling

Weitlaner retractors are used to maintain tissue exposure during appropriate surgical procedures. This model may be considered when a self-retaining retractor with sharp tissue-engaging prongs is required. Its suitability depends on the verified design, intended use, and anatomical area.

Before use, inspect the prongs for bending, damage, or irregularities and confirm that the instrument opens and closes smoothly. Ensure that the retaining mechanism operates correctly. Place and adjust the retractor under appropriate clinical control, applying only the necessary retraction force. Sharp prongs should be handled carefully during positioning, removal, transport, and cleaning.

Cleaning, Sterilization, and Maintenance

If supplied as a reusable instrument, the Weitlaner Retractor must be cleaned, inspected, and sterilized according to the manufacturer's validated instructions and the healthcare facility's infection-control procedures. Pay particular attention to the sharp prongs, joints, and retaining mechanism, where biological debris may accumulate.

Inspect the instrument after cleaning for corrosion, deformation, restricted movement, or damage to the tips. Follow the manufacturer's instructions for approved cleaning agents, sterilization cycles, drying, and storage. Confirm the material composition, reusable status, and supplied sterile condition before clinical use.

Selecting the Appropriate Weitlaner Retractor

When selecting a Weitlaner Retractor, consider its overall length, prong configuration, tip style, opening range, and intended surgical application. The 16 cm length and sharp 3x4 prongs distinguish this model, while the precise working dimensions should be confirmed with the manufacturer.

This retractor provides a self-retaining option for surgical instrument inventories that require sustained tissue separation with sharp prong engagement. Correct selection, careful placement, and appropriate reprocessing are essential for proper instrument use and maintenance.

Key Features

  • Weitlaner-style self-retaining surgical retractor

  • Overall length: 16 cm (160 mm)

  • Sharp prong configuration

  • 3x4 prong arrangement

  • Designed to maintain tissue separation and operative exposure

  • Sharp tips for secure tissue engagement when appropriate

  • Retaining mechanism helps maintain the selected retraction position

  • Exact opening range and prong dimensions require confirmation

  • Material composition not specified in the product title

  • Cleaning and sterilization according to manufacturer instructions

Product Specifications

SpecificationDetails
Product NameWeitlaner Retractor
Instrument TypeSelf-retaining surgical retractor
Overall Length16 cm
Metric Length160 mm
Prong Configuration3x4
Prong StyleSharp
Retaining DesignSelf-retaining
Locking MechanismExact design not specified
Maximum OpeningNot specified
Prong LengthNot specified
MaterialNot specified
Primary FunctionMaintaining tissue separation and surgical exposure
Reusable StatusConfirm with manufacturer
Sterile StatusNot specified
ReprocessingFollow manufacturer-validated instructions

Frequently Asked Questions

1. What is a Weitlaner Retractor used for?

A Weitlaner Retractor is used to maintain tissue separation and provide surgical exposure during appropriate procedures. Its self-retaining design helps hold the operative field open without continuous manual traction.

2. What is the length of this Weitlaner Retractor?

The specified overall length is 16 cm, equivalent to 160 mm.

3. What does 3x4 prongs mean?

The 3x4 designation describes the stated prong arrangement on the retractor's opposing working ends. Confirm the exact distribution with the manufacturer if precise configuration details are required.

4. What is the difference between sharp and blunt Weitlaner Retractors?

Sharp prongs are designed to engage tissue more securely when anchoring is appropriate, while blunt prongs have non-sharp-pointed tips. The correct choice depends on the procedure and the tissue involved.

5. Does this Weitlaner Retractor have a self-retaining mechanism?

The Weitlaner design is self-retaining and is intended to maintain tissue retraction. Confirm the exact locking and adjustment mechanism for this specific model.

6. What material is this retractor made from?

The material is not specified in the product title. Confirm the exact material and grade with the manufacturer before purchasing.

7. How should a sharp-prong Weitlaner Retractor be cleaned?

Follow the manufacturer's validated reprocessing instructions. Carefully clean around the sharp prongs, joints, and retaining mechanism, and inspect the instrument before sterilization.

8. What should be checked before using this retractor?

Inspect the sharp prongs for damage, confirm the retaining mechanism functions correctly, and verify that the instrument's size and configuration are suitable for the intended procedure.